Top-of-the range in the EZ-series, and worth considering if you have a type B camera (and are unlikely ti upgrade to a type A camera in the near future). A-TTL flash mode. Guide number of 54 (ISO 100m) at 105mm zoom head setting.

Coverage down to 18mm using built-in diffuser panel. Tilt and swivel head.

EOS magazine, December 2003, page 38

Type: clip-on type automatic flash unit with direct-coupled contacts (including AF auxiliary light corresponding to 5 focusing points, A-TTL pre-flash, auto zoom and bounce functions)
Flash duration: 1.2ms or less during normal firing; 2.3 ms or less during quick firing.
Coverage angle:
• auto zoom mode: automatically set according to focal length of the lens in use (settings: 24, 28, 35, 50, 70, 80, 105)
• manual zoom mode: manually set by pressing the zoom button
• wide panel: flash coverage for super-wide-angle lenses down to 18mm is possible by covering the flash head with built-in wide panel
Flash modes:
• normal firing
• quick firing
• stroboscopic flash: stroboscopic frequency and no. of bursts each settable in 31 steps
• pre-flash: for measuring A-TTL distance information
• test firing: by pressing the test firing button
Flash head positions:

Direction

Maximum rotation angle

Click stops

Up

90°

0°, 60°, 75°, 90°

Left

180°

0°, 60°, 75°, 90°, 120°, 150°, 180°

Right

90°

0°, 60°, 75°, 90°

Down

0°, 7°

Exposure control modes: A-TTL program automatic flash, TTL program automatic flash, manual
Flash metering system: TTL automatic flash metering of light reflected off the film plane
Flash exposure compensation:
• automatic flash output reduction control provided in daylight fill-in flash situations
• manual compensation can be set on the flash within a range of ± stops in 1/3-stop increments. (possible in all shooting modes except fully-automatic shooting modes.)
• with some EOS models, flash exposure compensation is possible from the camera side by turning the main dial
Flash coupling range (50mm f1.4, ISO 100): A-TTL normal firing: 0.5~30m / 1.7~99ft, quick firing: 0.5~7.5m / 1.7~25ft (min) to 0.5~21m / 1.7~69.3ft (max.)
Flash change completion indicators: when the ready lamp lights red, normal firing is possible; when the ready lamp lights green, quick firing is possible
Auxiliary light & effective distance range: corresponds to 5 focusing points. Center: approx. 0.5~15m / 1.7~49.5ft (in dark situations); left/right: approx. 0.7~6m / 2.3~19.8ft (in dark situations)
Power supplies:
Built-in power supply:
• four AA-size alkaline-maganese batteries (LR6/AM-3)
• four AA-size Ni-Cd batteries (KR15/51)
• four AA-size lithium batteries
External power supplies:
• six AA-size alkaline-maganese batteries (LR6/AM-3)
• battery magazine TP (holds six C-size alkaline-maganese batteries (LR14/AM-2)
• Ni-Cd pack TP
Save energy function: when the main switch is set to the SE position, the power automatically turns off after 90 seconds of inactivity
Mode memory: The 540EZ automatically memorises its status information including the control mode and zoom position when the power is turned off
Dimensions: 80 (W) x 138 (H) x 112 (D)mm
Weight: 405g (main unit only)
Guide numbers (ISO 100m):

Covergae angle (mm)

18

21

28

35

50

70

80

105

Normal (full power) firing (G-No)

16

28

30

36

42

46

50

54

Quick firing

Same as manual firing at 1/2-1/16 output levels

Manual firing (guide number)

1/1

16

28

30

36

42

46

50

54

1/2

11.3

19.8

21.2

25.5

29.7

32.5

35.4

38.2

1/4

8

14

15

18

21

23

25

27

1/8

5.7

9.9

10.6

12.7

14.8

16.3

17.7

19.1

1/16

4

7

7.5

9

10.5

11.5

12.5

13.5

1/32

2.8

4.9

5.3

6.4

7.4

8.1

8.8

9.5

1/64

2

3.5

3.8

4.5

5.3

5.8

6.3

6.8

1/128

1.4

2.5

2.7

3.2

3.7

4.1

4.4

4.8

* The 18mm coverage angle figures are for when the built-in wide panel is used
• For guide numbers based on feet instead of meters, perform the following calculation: guide no. (ft) = guide no. (m) x 3.3
Battery life (No. of bursts) and recycle time:

Power supply

Battery life (No. of bursts) (approx.)

Recycle time (sec.)

Quick firing (approx.)

Normal firing (approx.)

Built-in power supplies

4 AA-size alkaline

120~800

0.2~2

0.2~12

4 AA-size Ni-Cd

50~350

0.2~1.5

0.2~6

External power supplies

Transistor pack E with Ni-Cd pack TP

350~2000

0.2~1

0.2~3

Transistor pack E (4 alkaline C-cells)

400~2500

0.2~1.5

0.2~5

Compact battery pack E (LR6/AM-3)

400~2500

0.2~1.5

0.2~5

* In the battery life column, figures on the right indicate the number of bursts in A-TTL mode, and figures on the left indicate the number of bursts in manual (1/1) mode.
The number of bursts possible at the 1/2, 1/4, 1/8, 1/16, 1/32, 1/64 and 1/128 manual power settings are greater than number of bursts possible at the full-power (1/1) setting by factors of 2, 4, 8, 10, 12, 15 and 18, respectively.
* In the recycle time column, the left-hand values are the flash recycle times in A-TTL mode, and the right-hand values are the flash cycle times in manual mode at full (1/1) power.